How to Repressurise a Boiler

Home › Guides › How to Repressurise a Boiler

To repressurise a boiler, switch it off, open the filling loop valves until the pressure gauge reads between 1 and 1.5 bar, close the valves and switch the boiler back on. It takes a few minutes, needs no tools, and most combi and system boilers are made for the homeowner to do it. The pressure drops because water has left the sealed system, usually after bleeding a radiator or through a small leak. If the pressure falls again within a few days of topping it up, water is still leaving the system and it needs an engineer.

What should my boiler pressure be?

With the heating off and the system cold, the gauge on the front of most combi and system boilers should read between 1 and 1.5 bar. Some makers give a wider normal range of 1 to 2 bar, because the pressure rises a little as the water heats up, so check your own manual. Many boilers show a green band on the gauge to mark the normal range. The table below covers what each reading means.

Gauge reading (cold)What it meansWhat to do
Below 1 barUnder-pressurisedTop it up to 1 to 1.5 bar
1 to 1.5 barNormalNothing, the system is balanced
Above 2 barOver-pressurisedBleed a radiator a little, then re-check

A boiler that has lost pressure will often tell you itself. Many modern boilers show a low-pressure error code, such as F1 on an Ideal boiler or F.22 on a Vaillant, and shut down until the pressure is restored. If the pressure is below 0.5 bar, water has definitely left the system. Do not keep running the heating with the pressure at zero: the boiler may lock out, and the pump can run dry.

How to repressurise a boiler with a filling loop

Most combi boilers have an external filling loop: a silver, flexible braided hose under the boiler, with a tap at each end, that connects the mains cold water pipe to the central heating return pipe. Follow these steps, and always check your manufacturer manual first, because filling arrangements differ between makes and models.

  1. Switch the boiler off and let the system cool down completely. Adding cold mains water to a hot boiler can cause thermal shock and crack the heat exchanger.
  2. Check the hose is connected at both ends. If your installer did not leave the flexible loop attached, screw it onto both brass connection valves underneath the boiler, hand tight.
  3. Position yourself so you can see the pressure gauge while reaching the valves. On some boilers the gauge sits on the pipework underneath, next to the filling loop.
  4. Open the valves slowly. Turn one valve so the handle lines up with the pipe, then open the second. You will hear water flowing into the sealed system.
  5. Watch the gauge rise. Close both valves as soon as it reaches 1 to 1.5 bar. Do not overfill the system past 2 bar: when the heating runs, the pressure rises by about half a bar on its own.
  6. Close both valves fully. A valve left slightly open keeps pushing the pressure up.
  7. Disconnect the filling loop. To comply with UK water regulations, unscrew and remove the braided hose from at least one end, and keep a cloth ready for drips.
  8. Switch the boiler back on and press reset if the display asks you to. Check the gauge again over the next day.

How to repressurise a boiler with a filling key

Some Worcester Bosch combi boilers use a built-in filling link with a removable key instead of a hose. The key is usually kept in a flap under the boiler. Push the key into the port at the front underside, line up the arrow with the open padlock symbol, and turn it until the gauge reads just over 1 bar. Then turn it back to the closed position and remove the key. Other boilers use a keyless lever or tap under the boiler that you hold open while watching the gauge. If your boiler has neither a hose nor a key, follow the instructions in your manual, because the filling point is different again.

Why is my boiler losing pressure?

A small drop after bleeding a radiator is normal, because letting air out also lets out a little water. Top it up once after bleeding and see if it holds. If the pressure keeps falling, water is leaving the system, and the usual causes are a leak, the pressure relief valve, or the expansion vessel.

  • A leak on a radiator valve, a joint or a pipe. Look for damp patches, rust marks or white crusty residue under radiators and around valves. Sometimes it is a pinhole in an old pipe under the floor, where you cannot see it.
  • The pressure relief valve letting water out. It drains through a small copper pipe that usually runs through the wall outside. If that pipe is wet or dripping, the valve needs looking at.
  • The expansion vessel inside the boiler losing its charge, which makes the pressure swing up and down as the system heats and cools.

Write the reading down and check it again after 24 hours, then after a week. A drop within a day is a leak to find; a drop over a season is normal. A sealed heating system loses a little pressure over a year, and topping it up once or twice is normal. Losing it every few days means water is leaving the system.

What if the pressure is too high?

If the gauge reads above 2 bar with the system cold, the system is overfilled. Bleed a radiator a little with the heating off, using a radiator key and a cloth, and watch the gauge fall back towards 1.5 bar. Then close the bleed valve and check the filling loop valves are fully closed, because a valve left slightly open keeps pushing the pressure up. If the pressure keeps rising on its own, or the relief valve keeps discharging water outside, stop and call an engineer: the fault is inside the boiler.

When to call a Gas Safe engineer

Topping up with the filling loop, reading the gauge, bleeding radiators and resetting the boiler once after topping up are safe for a homeowner to try. Everything inside the boiler casing is Gas Safe registered work: the relief valve, the expansion vessel, anything behind the casing, and finding and fixing a leak from the boiler itself. Always check the engineer is on the Gas Safe Register, by checking the seven-digit number on the ID card at gassaferegister.co.uk or by texting Gas and the number to 85080.

  • If you smell gas, leave the property, do not switch anything on or off, and call the National Gas emergency line on 0800 111 999 from outside.
  • If the pressure falls as soon as you close the filling loop, do not keep topping up. That is a significant leak or a relief valve fault, and repeated filling can do further damage.
  • If you are topping up more than once or twice a year, if the outside relief pipe is wet, or if there is a puddle under the boiler.
  • If water is dripping near the fused spur, sockets or the consumer unit. Switch off at the main switch only if it is dry and safe to reach.
  • If the boiler is dripping from the casing, switch it off.

A weekday call-out with diagnosis in London typically costs £60 to £125, often waived if the repair goes ahead, and labour is £80 to £140 an hour. A pressure fault, meaning the expansion vessel or the pressure relief valve, typically costs £120 to £280 with the part.

For the radiator jobs that go with this one, see our guide to bleeding a radiator for the cold-top problem, our guide to balancing radiators for radiators that heat unevenly across the house, our guide to a radiator cold at the bottom for sludge, and our boiler size calculator if the whole system is underpowered.

Frequently asked questions

What pressure should my boiler be?

Between 1 and 1.5 bar with the heating off and the system cold. Below 1 bar is under-pressurised, and above 2 bar is over-pressurised. Some makers give 1 to 2 bar as normal, so check your own manual.

Can I repressurise my boiler myself?

Yes, in a few minutes. Switch the boiler off and let it cool, open the filling loop valves until the gauge reads 1 to 1.5 bar, close both valves fully, disconnect the hose and switch the boiler back on. Anything inside the boiler casing is Gas Safe registered work.

Why does my boiler keep losing pressure?

Water is leaving the sealed system. The usual causes are a leak on a radiator valve, joint or pipe, a pressure relief valve letting water out through the copper pipe outside, or an expansion vessel that has lost its charge. A small drop after bleeding a radiator is normal.

What happens if I overfill my boiler?

The pressure rises further when the heating runs, and the relief valve may discharge water outside. Bleed a radiator a little with the heating off until the gauge falls back towards 1.5 bar, and check the filling loop valves are fully closed. If the pressure keeps rising on its own, call an engineer.

Sources

The normal range of 1 to 1.5 bar cold, the low-pressure codes F1 on Ideal and F.22 on Vaillant, the 7-step filling loop method, the warning about thermal shock from adding cold water to a hot boiler, and the UK water regulation to disconnect the hose follow a UK boiler repressurising guide updated in November 2026. The three filling loop types of external hose, internal key and keyless lever, the 6-step method, the causes of a leak, a relief valve or an expansion vessel, and the Gas Safe Register check follow a UK boiler repressurising guide. The 24-hour and one-week re-check, the rule that topping up once or twice a year is normal, the London call-out figures of £60 to £125 and the pressure fault figures of £120 to £280, and the gas emergency number 0800 111 999 follow a UK boiler pressure guide. The Worcester Bosch filling key method, the normal range of 1 to 2 bar from Baxi, and the warning against repeatedly repressurising when the pressure keeps falling follow a UK boiler pressure guide published in November 2026.