Log Burner Size Calculator

Home › Calculators › Log Burner Size Calculator

Room length, width and height to a log burner output in kilowatts, with a 10 percent adjustment for good or poor insulation.

Length: – × Width: – × Height: –Volume divided by 14 gives the base output in kW

A room 5 metres long, 4 metres wide and 2.5 metres high has a volume of 5 × 4 × 2.5 = 50 cubic metres. Dividing by 14 gives 50 ÷ 14 = 3.6 kilowatts, so a stove rated near 3.6 kW suits that room at average insulation. If you want the number for your own room, the calculator above gives it from your room size and insulation level.

How the divide by 14 rule works

Stove guides in the UK use a common starting rule: measure the room in metres, multiply length by width by height to get the volume in cubic metres, then divide by 14. The result is a rough guide to the heat output in kilowatts that the room needs, based on average insulation. It is a starting point, not a survey: glazing, ceiling height, open-plan links to other rooms and local climate all shift the real requirement, which is why a qualified installer should confirm the final size.

Insulation adjustment: 10 percent either way

Published stove guidance adjusts the base figure by about 10 percent for insulation: a well insulated newer home needs about 10 percent less, and an older draughty home needs about 10 percent more. This calculator applies that adjustment. A 50 cubic metre room gives 3.6 kW at average insulation, 3.2 kW when well insulated and 3.9 kW when poorly insulated. Choose the insulation setting that matches your home, not the one that gives the answer you hoped for, since an oversized stove causes as many problems as an undersized one.

What size for common room volumes

Room volumeBase output (volume ÷ 14)Typical room
30 m³2.1 kWSmall bedroom or study
50 m³3.6 kWAverage living room
70 m³5.0 kWLarge living room
100 m³7.1 kWOpen-plan living space

Oversized stoves and undersized stoves

An undersized stove runs flat out and still leaves the room cold. An oversized stove overheats the room, so it gets run with the air turned down, which leads to sooty glass, tar build-up in the flue and wasted fuel. That is why the aim is a stove rated near the calculated figure, not the largest stove that fits the fireplace. Note also the 5 kW threshold in UK building rules: stoves above 5 kW in newer or renovated homes usually need a permanent air vent, so a 5 kW stove is a common choice for an average living room for a practical reason as well as a heating one.

Before you buy: flue, vent and fuel

Size is only one part of the decision. The stove needs a suitable flue and hearth, the right ventilation for its output, and, in a smoke control area, a DEFRA exempt model. Burn wood with a moisture content of 20 percent or below, and look for the Ready to Burn logo on bagged logs, since wet wood gives less heat, more smoke and more soot. A HETAS-registered installer surveys the room, the chimney and the ventilation together, so use this calculator to narrow the choice and let the installer confirm it.

Frequently asked questions

What size log burner do I need for a 50 cubic metre room?

About 3.6 kW at average insulation: 50 cubic metres divided by 14 is 3.6 kW. A well insulated room needs about 3.2 kW and a poorly insulated room about 3.9 kW.

How do you calculate log burner kW?

Multiply room length by width by height in metres to get the volume in cubic metres, then divide by 14. Adjust by about 10 percent down for good insulation or 10 percent up for poor insulation.

Is a 5 kW log burner enough for a living room?

A 5 kW stove suits a room of about 70 cubic metres at average insulation, which covers many larger living rooms. An average 50 cubic metre living room needs about 3.6 kW, so 5 kW would be oversized there.

What happens if a log burner is too big?

The room overheats, so the stove gets run with the air turned down. That causes sooty glass, tar build-up in the flue and wasted fuel. Pick a stove rated near the calculated output instead.

Sources

The divide by 14 rule and the 10 percent insulation adjustment follow published UK stove-sizing guidance, including Ideal Home and stove supplier guides, which agree on 1 kW per 14 cubic metres at average insulation. The 20 percent moisture limit for firewood follows the UK Ready to Burn standard. Outputs are a rough guide, and a qualified installer should confirm the size, flue and ventilation.

Changelog

  • 4 November 2026: calculator published.

Cite this page

APA: Wolveyes. (2026, November 4). Log Burner Size Calculator. Wolveyes. https://wolveyes.pk/calculators/log-burner-size-calculator/

MLA: “Log Burner Size Calculator.” Wolveyes, 4 Nov. 2026, https://wolveyes.pk/calculators/log-burner-size-calculator/

<iframe src="https://wolveyes.pk/calculators/log-burner-size-calculator/" width="100%" height="600" style="border:1px solid #E5E0D5;border-radius:8px;" title="Log Burner Size Calculator by Wolveyes"></iframe>
<p><a href="https://wolveyes.pk/calculators/log-burner-size-calculator/">Log Burner Size Calculator by Wolveyes</a></p>