Room size and ceiling height to the smoke CADR your air purifier needs, by the AHAM 2/3 rule and by air changes per hour.
A 12 ft by 15 ft bedroom with an 8 ft ceiling needs an air purifier rated at least 120 CFM smoke CADR. That figure comes from the AHAM 2/3 rule: room area in square feet times two thirds. At 4 air changes per hour the same room needs only 96 CFM, so the AHAM figure governs and the calculator recommends the larger of the two numbers. If you want the number for your own room, the calculator above gives it from length, width and ceiling height.
What CADR means
CADR stands for Clean Air Delivery Rate, measured in cubic feet per minute (CFM). It states how much filtered air a purifier delivers, and it is tested for three particle sizes: smoke, dust and pollen. Smoke CADR is usually the lowest of the three, which is why it is the right number to size by: a unit that passes on smoke passes on the rest. The room size printed on the box, by contrast, is a marketing estimate with no fixed test behind it, so two purifiers with the same box rating can have very different CADR values.
The two ways to size a purifier
The AHAM 2/3 rule is the quick method: minimum smoke CADR = room area in square feet × 2/3. It assumes a standard 8 ft ceiling and delivers roughly 5 air changes per hour. The volume method is the exact method: required CADR = room volume in cubic feet × air changes per hour ÷ 60. Use the volume method when your ceiling is not 8 ft, or when you want a specific air change rate rather than the AHAM default. The calculator shows both and recommends the larger.
Minimum smoke CADR by room size
| Room area | Minimum smoke CADR (2/3 rule) | Example room |
|---|---|---|
| 100 sq ft | 67 CFM | 10 × 10 ft bedroom |
| 150 sq ft | 100 CFM | 10 × 15 ft bedroom |
| 200 sq ft | 134 CFM | 12 × 17 ft living room |
| 300 sq ft | 200 CFM | 15 × 20 ft living room |
| 500 sq ft | 334 CFM | 20 × 25 ft open room |
Worked example: a 12 ft by 15 ft bedroom
Floor area is 12 × 15 = 180 sq ft. Room volume is 180 × 8 = 1,440 cu ft. At 4 air changes per hour, required CADR is 1,440 × 4 ÷ 60 = 96 CFM. By the AHAM 2/3 rule, minimum smoke CADR is 180 × 2/3 = 120 CFM. The recommendation is 120 CFM, the larger figure. At 6 air changes per hour, the volume method gives 1,440 × 6 ÷ 60 = 144 CFM, which then governs instead.
Ceiling height, open rooms and smoke season
A room with a 12 ft ceiling holds half as much air again as the same floor area with an 8 ft ceiling, so the 2/3 rule alone understates it: use the volume method and its air change rate. The same applies to a room left open to a hallway, because the purifier ends up cleaning the joined space, not just the room on the label. In wildfire smoke season, published guidance suggests sizing up to a 1:1 ratio, a smoke CADR equal to the full room area in square feet, rather than two thirds of it.
Mistakes that leave a purifier undersized
Trusting the box room size is the first mistake, because it is not a tested figure. Ignoring ceiling height is the second, because volume, not floor area, is what the purifier moves. Buying one unit for an open-plan space and expecting it to cover the whole plan is the third: a portable purifier is built for one enclosed room. A little headroom above the minimum is worth having, because it lets the unit run on a lower, quieter speed and still deliver the air changes you sized for.
Sizing a room appliance for cooling rather than cleaning is a different job: our AC BTU Calculator sizes air conditioning from floor area, ceiling height and insulation in the same way.
Frequently asked questions
What CADR do I need for a 300 sq ft room?
At least 200 CFM smoke CADR by the AHAM 2/3 rule: 300 times two thirds is 200. With a ceiling above 8 ft, check the volume method too and take the larger figure.
Is a bigger purifier always better?
A little headroom above the minimum helps, because the unit can run on a lower, quieter speed and still hit your air change target. Far above the minimum, you pay more and gain little, so size to the room, then add modest headroom.
Why size by smoke CADR instead of dust or pollen?
Smoke CADR is usually the lowest of the three ratings, since smoke particles are the smallest tested. A unit sized on smoke CADR covers dust and pollen at the same rating.
How many air changes per hour do I need for allergies?
Four to five air changes per hour is the range commonly recommended for allergy relief. The AHAM 2/3 rule at a standard 8 ft ceiling delivers about 5 air changes per hour.
Related calculators
- AC BTU Calculator
- Heating Cost Calculator
- Appliance Electricity Cost Calculator
- Fridge Running Cost Calculator
- LED Savings Calculator
Sources
Minimum smoke CADR = room area in square feet × 2/3, from the Association of Home Appliance Manufacturers (AHAM) rule for portable air purifiers. Required CADR at a chosen air change rate = room volume in cubic feet × air changes per hour ÷ 60. Four to five air changes per hour is the range commonly recommended for allergy relief, and a 1:1 ratio is published guidance for sizing during wildfire smoke events.
Changelog
- 30 October 2026: calculator published.
Cite this page
APA: Wolveyes. (2026, October 30). Air Purifier Size Calculator. Wolveyes. https://wolveyes.pk/calculators/air-purifier-size-calculator/
MLA: “Air Purifier Size Calculator.” Wolveyes, 30 Oct. 2026, https://wolveyes.pk/calculators/air-purifier-size-calculator/
<iframe src="https://wolveyes.pk/calculators/air-purifier-size-calculator/" width="100%" height="600" style="border:1px solid #E5E0D5;border-radius:8px;" title="Air Purifier Size Calculator by Wolveyes"></iframe>
<p><a href="https://wolveyes.pk/calculators/air-purifier-size-calculator/">Air Purifier Size Calculator by Wolveyes</a></p>