Radiator Size Calculator

Home › Calculators › Radiator Size Calculator

Room dimensions, room type, facing and glazing to the radiator output in BTU per hour and kilowatts.

BTU/hLength: – × Width: –

A 12 ft by 12 ft lounge with an 8 ft ceiling needs a radiator output of 5,760 BTU per hour, which is 1.7 kW. The room volume is 12 × 12 × 8 = 1,152 cubic feet, and the lounge factor is 5 BTU per cubic foot, so 1,152 × 5 = 5,760 BTU per hour. If you want the number for your own room, the calculator above gives it from length, width, ceiling height, room type, facing, glazing and French windows.

The volume rule: BTU per cubic foot by room type

The classic UK radiator rule sizes by room volume, not floor area alone, because ceiling height changes how much air must be heated. Lounges and dining rooms are kept warmest, so they use the highest factor, bedrooms sit in the middle, and kitchens and common areas, which gain heat from cooking and appliances, use the lowest. Multiply the room volume in cubic feet by the factor for the room type.

Room typeBTU per cubic foot
Lounge or dining room5
Bedroom4
Kitchen or common area3

Adjustments for facing, windows and glazing

Three adjustments cover the common heat loss differences. A north-facing room loses more heat, so add 15 percent. French windows are a large glazed area, so add 20 percent. Double glazing loses less heat than single glazing, so deduct 10 percent. The calculator applies them in turn: a north-facing, double-glazed room multiplies by 1.15, then by 0.90.

FeatureAdjustment
North-facing roomAdd 15%
French windowsAdd 20%
Double glazingDeduct 10%

Worked example: a 5 m by 4 m lounge

The room is 5 m by 4 m with a 2.4 m ceiling, which is 48.0 cubic metres or 1,695 cubic feet. At the lounge factor of 5 BTU per cubic foot, the base figure is 1,695 × 5 = 8,475 BTU per hour. The room faces north, so multiply by 1.15, and it has double glazing, so multiply by 0.90: 8,475 × 1.15 × 0.90 = 8,772 BTU per hour, which is 2.6 kW. Pick the first radiator size rated above 8,772 BTU per hour, and check the rating at your system temperature, because radiators rated at ΔT50 for gas boilers give about half their rated output on a low-temperature heat pump system at ΔT30.

One radiator or two

A room longer than 6 metres in any one direction heats more evenly with two smaller radiators than with one large unit, because heat spreads from both ends instead of pooling at one wall. The same applies to L-shaped rooms: size each part of the room separately and add the two figures. When no single radiator matches the calculated figure, always pick the next size up, since an undersized radiator runs without pause and still leaves the room cold, while a slightly oversized one is held back by its thermostatic valve.

Once the size is right, keep the radiator working at full output: our guide How to Bleed a Radiator clears trapped air that leaves the top cold. For the temperature to hold the house at through winter, see our guide What Temperature Should You Set Your Thermostat in Winter?.

Frequently asked questions

What size radiator do I need for a 12 ft by 12 ft room?

A 12 ft by 12 ft lounge with an 8 ft ceiling needs 5,760 BTU per hour, which is 1.7 kW: volume 1,152 cubic feet × 5 BTU per cubic foot. A bedroom the same size needs 4,608 BTU per hour at the bedroom factor of 4.

How do I convert radiator BTU to kilowatts?

Divide BTU per hour by 3,412. A 5,760 BTU per hour radiator is 1.7 kW, and a 10,000 BTU per hour radiator is 2.9 kW. UK radiator specs list both figures, so compare the same unit on both sides.

Does a north-facing room need a bigger radiator?

Yes, by about 15 percent. A north-facing room loses more heat through its outside wall, so the calculator adds 15 percent for north-facing rooms and 20 percent for French windows, while double glazing deducts 10 percent.

Should I pick a radiator exactly at the calculated BTU?

Pick the first rated size above the calculated figure. Radiators come in fixed sizes, so an exact match is rare, and a slightly larger radiator is controlled by its thermostatic valve, while an undersized one cannot reach the room temperature.

Sources

The 5, 4 and 3 BTU per cubic foot room factors, the 15 percent north-facing addition, the 20 percent French windows addition and the 10 percent double glazing deduction follow the classic UK radiator sizing rule published by DIY guides. The ΔT50 to ΔT30 output ratio of about half follows UK radiator sizing guides for heat pump systems. The conversion uses 1 kW = 3,412 BTU per hour.

Changelog

  • 2 November 2026: calculator published.

Cite this page

APA: Wolveyes. (2026, November 2). Radiator Size Calculator. Wolveyes. https://wolveyes.pk/calculators/radiator-size-calculator/

MLA: “Radiator Size Calculator.” Wolveyes, 2 Nov. 2026, https://wolveyes.pk/calculators/radiator-size-calculator/

<iframe src="https://wolveyes.pk/calculators/radiator-size-calculator/" width="100%" height="600" style="border:1px solid #E5E0D5;border-radius:8px;" title="Radiator Size Calculator by Wolveyes"></iframe>
<p><a href="https://wolveyes.pk/calculators/radiator-size-calculator/">Radiator Size Calculator by Wolveyes</a></p>