How Much Does It Cost to Run Central Heating?

Home › Guides › How Much Does It Cost to Run Central Heating?

A home needing 10 kilowatts of heat, heated by a boiler running at 90 percent efficiency, uses 11.1 kilowatt hours of gas per hour at full input. At 7.33 pence per kilowatt hour, that is about 81 pence per hour. That is the full-input figure, so the real cost is usually lower, since a boiler rarely runs at full input for a whole hour. This guide works through the formula, a home-size table, and how gas, electric heating and heat pumps compare, all at UK rates in pounds.

The formula: cost per hour

Cost per hour equals boiler gas input in kilowatts multiplied by your gas unit rate in pence per kilowatt hour. Gas input is not the same as heat output: a boiler turns part of its gas into heat and loses the rest, so gas input equals heat output divided by efficiency. A 10 kilowatt heat demand at 90 percent efficiency needs 10 ÷ 0.90 = 11.1 kilowatt hours of gas per hour. Multiply by the unit rate to get the cost: 11.1 × 7.33 pence = 81.4 pence, which rounds to about 81 pence per hour.

The unit rates used here are the Ofgem July to September 2026 average Direct Debit rates: 7.33 pence per kilowatt hour for gas and 26.11 pence per kilowatt hour for electricity. These are national averages under the price cap, not your tariff, so check your own bill or tariff and swap in your rate if it differs. A rate only a penny higher or lower moves the hourly cost by about 11 pence on the 10 kilowatt example, so your tariff is the single biggest variable after heat demand.

Worked example: 10 kilowatts of heat at 90 percent efficiency

Heat demand is 10 kilowatts and boiler efficiency is 90 percent, so gas input is 10 ÷ 0.90 = 11.11 kilowatt hours per hour. At 7.33 pence per kilowatt hour, the cost is 11.11 × 7.33 = 81.4 pence per hour, about 81 pence. Run at full input for 6 hours, that is 81.4 × 6 = 488 pence, or £4.88 for the day. That day figure is an upper bound, not a typical day, because a boiler at full input for 6 hours straight means a cold house being heated hard, and most days the boiler cycles and modulates well below full input.

Why the real cost is usually below the full-input figure

A modern condensing boiler modulates, which means it turns its burner down as the house nears the thermostat setting instead of switching fully on and fully off. On a mild day it may run at a third of its rated input, and once the house is warm the thermostat cycles it off for stretches. Weather compensation, which lowers the radiator temperature on milder days, cuts input further. The full-input figure is still the right planning number, since it bounds the worst hour, but a bill built from it hour after hour overstates a normal heating day. For your own heater, room or appliance, run the numbers through our Heating Cost Calculator, which takes watts, hours and your rate directly.

Cost per hour by home size

The table below holds efficiency at 90 percent and the gas rate at 7.33 pence per kilowatt hour, and varies only the heat demand. Larger homes need more heat, and older or poorly insulated homes need more heat for the same floor area, so use the row that matches your heat demand rather than your floor area alone.

HomeHeat demandGas input per hourCost per hour at 7.33p per kWh
Small flat6 kW6.7 kWh49p
Two-bedroom home8 kW8.9 kWh65p
Three-bedroom semi-detached10 kW11.1 kWh81p
Four-bedroom detached14 kW15.6 kWh£1.14

Gas, electric heating and heat pumps compared

Gas is the cheapest per unit of heat at these rates, because gas costs 7.33 pence per kilowatt hour against 26.11 pence for electricity. Direct electric heating turns each kilowatt hour of electricity into one kilowatt hour of heat, so 10 kilowatts of heat from electric radiators costs 10 × 26.11 = 261 pence, or £2.61 per hour at full input, which is more than three times the gas figure. A heat pump changes the picture, because it moves heat rather than making it: at a seasonal efficiency of 3, meaning 3 units of heat per unit of electricity, 10 kilowatts of heat needs 10 ÷ 3 = 3.33 kilowatt hours of electricity, costing 3.33 × 26.11 = 87 pence per hour, close to the gas figure. The comparison turns on your tariff, your heat pump efficiency in cold weather, and your boiler efficiency, so run your own rates through the formula before choosing.

What else moves the bill

The standing charge sits on top of unit costs and does not change with hours of heating, so it is left out of the hourly figures here. Thermostat setting matters more than most people expect: each degree lower trims heat loss through walls and windows all day, which is why a setback at night or while out saves more than switching radiators off in single rooms. Draughts force the boiler to replace cold air leaking in, so sealing them cuts the heat demand itself; see our guide How to Draught-Proof Your Home for the room-by-room method. Radiator bleeding, covered in our guide How to Bleed a Radiator, keeps radiators heating fully, so the boiler reaches the thermostat setting sooner.

Frequently asked questions

How much does it cost to run central heating per hour?

A home needing 10 kilowatts of heat at 90 percent boiler efficiency uses 11.1 kilowatt hours of gas per hour, which is about 81 pence per hour at 7.33 pence per kilowatt hour. Smaller homes cost less and larger homes cost more, and the real cost is usually below the full-input figure because boilers modulate and cycle.

How do I work out my own central heating cost per hour?

Divide your heat demand in kilowatts by your boiler efficiency as a decimal to get gas input, then multiply by your gas unit rate. For example, 10 divided by 0.90 is 11.1 kilowatt hours, and 11.1 times 7.33 pence is about 81 pence per hour. Use the rate from your own tariff, not the national average, for an exact figure.

Is a heat pump cheaper to run than a gas boiler?

At the July to September 2026 average rates, a heat pump at an efficiency of 3 costs about 87 pence per hour for 10 kilowatts of heat, close to the 81 pence gas figure, while direct electric heating costs £2.61 per hour. The answer turns on your tariff and your heat pump efficiency in cold weather.

Does the standing charge count in the hourly cost?

No. The standing charge is a fixed daily amount that does not change with hours of heating, so the hourly figures here cover unit costs only. Add your standing charge separately when you total a bill.

Sources

The unit rates of 7.33 pence per kilowatt hour for gas and 26.11 pence per kilowatt hour for electricity are the Ofgem July to September 2026 average Direct Debit rates, used here as the cited reference rates with a check-your-tariff caveat, since they are national averages, not individual tariffs. The formula is gas input equals heat output divided by boiler efficiency, and cost per hour equals gas input multiplied by the unit rate. The heat pump comparison uses an efficiency of 3 units of heat per unit of electricity, and direct electric heating is counted at one unit of heat per unit of electricity.

Changelog

  • 3 November 2026: guide published.