Floor area, insulation and shower flow to the boiler size in kW: combi or system, plus the cylinder size for your home.
A 90-square-metre home with average insulation and a shower flowing at 11 litres a minute needs a 28 kW combi boiler. The heating demand is only 6.8 kW, while heating the shower water needs 26.8 kW, so hot water sets the size, not heating. That pattern holds for most UK homes: the combi must heat water on demand, which takes far more power than keeping the rooms warm. Enter your floor area, insulation level, boiler type and shower flow in the calculator above.
Why does hot water set the size of a combi?
Heating water as it flows takes power in direct proportion to the flow rate. The power needed is the flow in litres a minute times 4.18 times a 35-degree temperature rise, divided by 60. A good shower at 11 litres a minute needs about 26.8 kW, while the same home needs only 6.8 kW to stay warm. The table below shows how the hot-water demand rises with flow.
| Shower flow | Hot-water power needed |
|---|---|
| 8 litres a minute | 19.5 kW |
| 10 litres a minute | 24.4 kW |
| 11 litres a minute | 26.8 kW |
| 12 litres a minute | 29.3 kW |
| 14 litres a minute | 34.1 kW |
Check the table against the calculator: 12 litres a minute times 4.18 times 35, divided by 60, is 29.26 kW, which rounds to 29.3 kW.
What size combi boiler do I need?
UK manufacturer and installer guidance gives these starting bands. They are a starting point, not a substitute for a heating survey, since two homes with the same number of bedrooms can have very different heat loss.
| Home | Combi size |
|---|---|
| Flat or 1 to 2 bedrooms, 1 bathroom | 24 to 28 kW |
| 3 bedrooms, 1 to 2 bathrooms | 28 to 32 kW |
| 4 bedrooms, 2 or more bathrooms | 32 to 40 kW |
A 35 to 40 kW combi only works when showers are not used at the same time and the mains water flow and pressure are strong. If two showers often run together, a system boiler with a cylinder is usually the better choice.
How is heating demand worked out?
Heating demand is the floor area times a heat loss rate that depends on insulation: 50 watts per square metre for good insulation, 75 for average insulation and 100 for poor insulation. A 90-square-metre home with average insulation needs 90 times 75, which is 6,750 watts, or 6.8 kW. The table below shows the demand for common home sizes.
| Floor area | Good insulation | Average insulation | Poor insulation |
|---|---|---|---|
| 60 m² | 3.0 kW | 4.5 kW | 6.0 kW |
| 90 m² | 4.5 kW | 6.8 kW | 9.0 kW |
| 120 m² | 6.0 kW | 9.0 kW | 12.0 kW |
| 150 m² | 7.5 kW | 11.3 kW | 15.0 kW |
What size system boiler do I need?
A system boiler stores hot water in a cylinder, so its output only has to cover space heating plus about 3 kW to reheat the cylinder. A 90-square-metre home with average insulation needs 6.8 kW for heating, so a 10 kW system boiler with a 150-litre cylinder is the starting point for one bathroom. The cylinder size follows the number of bathrooms: about 150 litres for one bathroom, 180 to 210 litres for two, and 250 to 300 litres or more for three or more. The calculator above gives both figures for your home.
When is a combi the wrong choice?
Choose a system boiler with a cylinder when two showers or baths are often used at the same time, when the mains flow is weak, or when the home has five or more bedrooms. A combi can only heat one outlet at full flow, so a second shower opened mid-wash drops the temperature at both. Low mains pressure has the same effect even on a large combi. A heating engineer checks the mains flow and pressure before recommending a model, since those two numbers decide whether a combi can deliver its rated output at all.
Who should confirm the size?
This calculator gives an indicative size band from floor area, insulation and shower flow. The final size should be confirmed by a Gas Safe registered engineer from a room-by-room heat loss calculation, the hot-water demand, the mains flow and pressure, and the manufacturer data for the exact boiler model. Gas boilers in the UK must be installed by a Gas Safe registered engineer.
Frequently asked questions
What size boiler do I need for a 3 bedroom house?
A 3 bedroom house usually needs a 28 to 32 kW combi, or a 12 to 18 kW system boiler with a 180 to 210 litre cylinder. The combi size is set by the shower flow, while the system size follows the heating demand plus 3 kW for cylinder reheat.
Why does a combi need more kW than a system boiler?
A combi heats water on demand, so it must deliver the full hot-water power at once: about 26.8 kW for a shower at 11 litres a minute. A system boiler stores hot water in a cylinder, so its output only has to cover space heating plus about 3 kW of reheat.
How do I work out my heating demand?
Multiply the floor area in square metres by a heat loss rate: 50 watts per square metre for good insulation, 75 for average and 100 for poor. A 90 square metre home with average insulation needs 6.8 kW of heating.
What size hot water cylinder do I need?
About 150 litres for one bathroom, 180 to 210 litres for two bathrooms, and 250 to 300 litres or more for three or more bathrooms. The cylinder size follows the number of bathrooms, not the boiler output.
Sources
The 50, 75 and 100 watts per square metre heat loss bands, the hot-water formula of flow times 4.18 times a 35-degree rise divided by 60, the 3 kW cylinder reheat allowance and the cylinder size bands follow published UK boiler size calculators. The combi size bands by home size follow British Gas, Ideal Heating and Rix guidance. Gas boilers must be installed by a Gas Safe registered engineer.
Changelog
- 7 November 2026: calculator published.
Cite this page
APA: Wolveyes. (2026, November 7). Boiler Size Calculator. Wolveyes. https://wolveyes.pk/calculators/boiler-size-calculator/
MLA: “Boiler Size Calculator.” Wolveyes, 7 Nov. 2026, https://wolveyes.pk/calculators/boiler-size-calculator/
<iframe src="https://wolveyes.pk/calculators/boiler-size-calculator/" width="100%" height="600" style="border:1px solid #E5E0D5;border-radius:8px;" title="Boiler Size Calculator by Wolveyes"></iframe>
<p><a href="https://wolveyes.pk/calculators/boiler-size-calculator/">Boiler Size Calculator by Wolveyes</a></p>